This page was exported from Braindump2go Exam Dumps Free Download [ https://www.pass4surevce.com ] Export date:Mon Apr 29 1:28:03 2024 / +0000 GMT ___________________________________________________ Title: [2017-New-Version]100% Real NS0-507 Exam Dumps and NS0-507 Exam Questions 528Q-Braindump2go[46-60] --------------------------------------------------- 2017 March NS0-507 Exam Dumps with PDF and VCE Free Released Today!Free Download NS0-507 Exam Dumps (PDF & VCE) 528Q&As (2017 Version!) from www.Braindump2go.com  Today! 100% Real Exam Questions! 100% Exam Pass Guaranteed! 1.|2017 Version NS0-507 Exam Dumps (PDF & VCE) 528Q&As Download:http://www.braindump2go.com/ns0-507.html 2.|2017 Version NS0-507 Exam Questions & Answers Download:https://1drv.ms/f/s!AvI7wzKf6QBjgnjcpE8O4Ejp86Pw QUESTION 46Click the Exhibit button.After mapping the LUN on the cluster, you are not able to see in on the Windows 2012 host.cl01::>igroup show ¬-instanceVserver Name: svm1Igroup Name: ig1-winProtocol: iscsiOS Type: WindowsPortset Binding Igroup: -Igroup UUID: 358338ba-cfd6-11df-a9ab-123478563412Initiators: iqn.1991-05.com.microsoft: host1 (notlogged in)Referring to the exhibit, what is the problem? A.    An administrator is not logged into the host.B.    The iSCSI target has not been added to the host.C.    The OS type should be windows_2008.D.    The OS type should be windows_gpt. Answer: B QUESTION 47You want to prevent an FCoE frame from being split into two Ethernet frames.What is the minimum required frame size that will satisfy this requirement? A.    9216B.    2240C.    1512D.    9000 Answer: B QUESTION 48Click the Exhibit button.A storage administrator has the configuration shown in the exhibit.In which scenario would a volume move be successful?cl01::>vserver show -¬vserversvm1Vserver: svm1Vserver Type: dataVserver UUID: 1630b8eb-c2a6-11e4-a7dd-123478563865Root Volume: svm1_rootAggregate: Node1_aggr1,Node2_aggr1Name Service Switch: file,nisAllowed Protocols: fcpDisallowed Protocols: nfs,cifs, iscsi, ndmpIs Vserver with InfiniteVolume: falseQoS Policy Group: -cl01::>vserver show ¬-vserversvm2Vserver Type: dataVserver UUID: 1630b8eb-c2a6-11e4-a7dd-123478563412Root Volume: svm2_rootAggregate: Node1_aggr1,Node2_aggr1, Node1_aggr2Name Service Switch: file,nisAllowed Protocols: fcpDisallowed Protocols: nfs,cifs, iscsi, ndmpIs Vserver with InfiniteVolume: falseQoS Policy Group: -cl01::> A.    from svm1 aggregate Node1_aggr1 to svm1 aggregate Node2_aggr1B.    from svm1 aggregate Node1_aggr1 to svm2 aggregate Node1_aggr2C.    from svm2 aggregate Node1_aggr1 to svm2 aggregate Node1_aggr2D.    from svm1 aggregate Node1_aggr1 to svm1 aggregate Node1_aggr2 Answer: A QUESTION 49Click the Exhibit button.cl01::>igroup show ¬-vserversvm1VserverIgroup Protocol OSType Initiators--------- ------------- -------- --------- -------------------------------------svm1 esx_cluster mixed vmware20:00:00:25:b5:11:a0:01,20:00:00:25:b5:11:b0:01,iqn.1998-01.com.vmware:esx02cl01::>A customer is provisioning storage for two ESXi hosts using FCoE with CNA adapters. The customer mapped the LUN to the igroup shown in the exhibit. After scanning for new devices, the LUN is only seen by one of the ESXi hosts.What caused the problem? A.    One of the hosts is added in the igroip via iSCSI IQN.B.    The igroup protocol needs to be configured as FCP.C.    The switch zoning configuration does not include the correct initiators.D.    The LIFs are not on their home ports. Answer: A QUESTION 50An administrator wants to provide isolation among physical devices connected to the same FCP fabric. Which Cisco switch feature accomplishes this task? A.    VSANB.    FSIPC.    LUN maskingD.    logical domains Answer: AExplanation:VSANs provide the following capabilities:lsolate devices physically connected to the same fabric. http://www.cisco.com/en/US/products/ps5989/prod_troubleshooting_guide_chapter09186a008067a306.html QUESTION 51You are creating a logical diagram for an FCP SAN solution.You need to show connectivity between which three sets of components? (Choose three.) A.    management port and ACP cablingB.    inter-cluster network ports and hostsC.    hosts and FCP switchesD.    hosts and FCoE switchesE.    FCP switches and storage controller Answer: CDE QUESTION 52When designing a new SAN solution, which three components should be verified with the IMT? (Choose three.) A.    the connection protocolB.    the patch panel make and modelC.    host OS type and versionD.    the type of Ethernet switchE.    the clustered Data ONTAP version Answer: ACE QUESTION 53Which two port personality combinations are valid for the onboard UTA2 ports on a FAS8040 controller? A.    e0e/0e -¬ fce0f/0f ¬- fce0g/0g -¬ cnae0h/0h -¬cnaB.    e0e/0e -¬ fce0f/0f ¬- cnae0g/0g -¬ fce0h/0h ¬-cnaC.    e0e/0e -¬ fce0f/0f ¬- fce0g/0g -¬ fce0h/0h ¬-cnaD.    e0e/0e ¬- cnae0f/0f ¬-cnae0g/0g -¬ fce0h/0h ¬- fc Answer: AD QUESTION 54You are asked to migrate a SAN LIF to a node that was recently added to your cluster. The following CLI command was provided to you to complete the migration:network interface modify -¬vserver svm1 ¬-lif lif1 ¬home ¬-node cl01-04 ¬-homeport 6aWhich step is missing? A.    All hosts connecting to the controller through lif1 must be shut down.B.    The LIF must first be added to a portset.C.    Your zoning must be updated on the upstream switch.D.    The LIF must be put in a status-admin down state. Answer: A QUESTION 55A customer has recently deployed a clustered Data ONTAP 8.3 system and is trying to mount LUNs to a Windows 2012 Server using the iSCSI protocol. They are using Cisco Nexus 5548 network switches and the network administrator has informed the storage administrator that the ports are set to switchport mode trunk. The storage administrator has also been informed that the host and storage should be using VLAN 400 for iSCSI traffic. When the storage administrator attempts to add the SVM as an iSCSI target, it fails to connect.What is causing the problem? A.    The storage administrator has not enabled VLAN tagging on the storage ports.B.    Clustered Data ONTAP 8.3 does not support the iSCSI protocol on a VLAN tagged interface.C.    Windows 2012 Server does not support the iSCSI protocol on a VLAN tagged interface.D.    Clustered Data ONTAP 8.3 does not support running iSCSI on a VLAN ID below 1024. Answer: A QUESTION 56Click the Exhibit button.Referring to the exhibit, how many paths to the LUN are visible from the host?  A.    16B.    8C.    24D.    32 Answer: B QUESTION 57Which command enables the FC protocol on clustered Data ONTAP? A.    vserverfpolicy enable ¬-vserver<node_name> ¬-policy ¬name <policy_-name> ¬-sequence¬ number <seq_num>B.    vserverfcp create ¬-vserver<vserver_name> ¬-status ¬-adain upC.    node run node <node_name>fcadmincongig -¬eD.    vserveriscsi create-server<vserver_name> -target -alias <vserver_name> Answer: BExplanation:https://library.netapp.com/ecmdocs/ECMP1196817/html/vserver/fcp/create.html QUESTION 58A new server has been installed in your environment, but it is unable to see its NetApp boot LUN. You have narrowed the problem down to the zoning on your Cisco switch which has the following configuration:zone name z_NetAppvsan 400memberpwwn 20:00:00:25:b5:c0:ff:eememberpwwn 50:0a:09:84:8d:7c:51:d5zoneset name zs_NetAppvsan 400memberz_NetAppzoneset activate name zs_NetAppvsan 400What is the problem with your zoning configuration? A.    The memberdoes not reference the VSAN.B.    The zone and zoneset names do not match.C.    The zoneset was improperly activated.D.    The PWWN for your NetApp LIF is incorrect. Answer: D QUESTION 59A Windows 2012 Server has a 1 GB thin-provisioned LUN in a 10 GB thin-provisioned volume. After copying a 500 MB file to the LUN, you observe the LUN using 500 MB of space in the volume. After deleting the 500 MB file, you observe the LUN is still using 500 MB of space in the volume.Which two steps are required to reclaim the space? (Choose two.) A.    Press Optimize in the Windows Defragment and Optimize Drives utility.B.    Enablespace-allocationon the LUN.C.    Run TRIM on the host.D.    Empty the Recycle Bin on the host. Answer: BC QUESTION 60Click the Exhibit button.An administrator is attempting to map an iSCSI LUN to a Windows 2012 host, but the windows host fails to discover the iSCSI targets.Referring to the exhibit, what is the connectivity problem?  A.    The iSCSI service is running on svm1, but iSCSI is not licensed on the nodes.B.    The iSCSI LIFs are not currently on their home port.C.    The iSCSI LIFs are currently disabled.D.    The LIFs do not have a failover group defined. Answer: A !!!RECOMMEND!!! 1.|2017 Version NS0-507 Exam Dumps (PDF & VCE) 528Q&As Download:http://www.braindump2go.com/ns0-507.html 2.|2017 Version NS0-507 Study Guide Video: YouTube Video: YouTube.com/watch?v=W4qwgESs2qA --------------------------------------------------- Images: --------------------------------------------------- --------------------------------------------------- Post date: 2017-03-10 06:01:43 Post date GMT: 2017-03-10 06:01:43 Post modified date: 2017-03-10 06:01:43 Post modified date GMT: 2017-03-10 06:01:43 ____________________________________________________________________________________________ Export of Post and Page as text file has been powered by [ Universal Post Manager ] plugin from www.gconverters.com