QUESTION 16
You currently have the following configuration on your cluster:
cl01::>igroup show -¬instance
Vserver Name: svm1
Igroup Name: ig2
Protocol: mixed
OS Type: linux
Portset Binding Igroup: ¬-
Igroup UUID: 3fb136c7¬-cfd6¬-11df¬-a9ab¬-123478563412
Initiators: ¬-
What must you do to limit the LIFs that are used by an initiator to access a LUN?

A.    Create a portset.
B.    Create an additional igroup.
C.    Change the protocol to iSCSI.
D.    Change the OS type to windows_gpt.

Answer: A
Explanation:
https://library.netapp.com/ecmdocs/ECMP1368525/html/GUID-5CC27202-A43F-429F-AB13-C70E7CD58E09.html 1

QUESTION 17
A customer has a 4-node cluster and wants to use iSCSI for LUN traffic.
Which license needs to be installed on the nodes?

A.    iSCSI
B.    SnapRestore
C.    CIFS
D.    FC

Answer: A

QUESTION 18
Click the Exhibit button.
cl01::>lun mapping show ¬-
vserver svm1 ¬-
path /vol/svm1_vol1/lun1 ¬-
igroup svm1-ig1
Vserver Name: svm1
LUN path: /vol/svm1_vol1/lun1
Volume Name: svm1_vol1
Qtree Name: ""
LUN Name: lun1
Igroup Name: svm1-ig1
Igroup OS Type: windows
Igroup Protocol Type: iscsi
LUN ID: 3
Portset Binding Igroup: -
ALUA: true
Initiators: iqn.1991-
05.com.microsoft: host1
LUN Node: cl01-04
Reporting Nodes: cl01-01,
cl01-02, cl01-03, cl01-04
You have a 2-node cluster. You have added an HA pair with all flash drives for a high-performance database that is currently experiencing performance problems on SAS drives.
The LUN shown in the exhibit is moved from cl01-01 to cl01-04 to address the problems.
What is the next step in this scenario?

A.    Rescan the host to discover the new LUN location.
B.    Remove the old path entries from the host.
C.    Remove the previous owner and partner from the reporting nodes list.
D.    Unmap the LUN, then remap the LUN.

Answer: C

QUESTION 19
Click the Exhibit button.
cl01::>iscsi portal show
Logical Status CurrCurr
Vserver Interface TPGT
Admin/Oper IP Address Node
Port Enabled
---------- ---------- ---- --
-------- ---------------- ----
------- ---- -------
svm1 1-a 1035 up/up
192.168.1.66 cl01-01 e0a true
svm1 1-b 1051 up/up
192.168.1.67 cl01-01 e0b true
svm1 2-a 1046 up/down
192.168.1.68 cl01-02 e0a true
svm1 2-b 1052 up/up
192.168.1.69 cl01-02 e0b true
Referring to the exhibit, which action would you take to troubleshoot the iscsi-2-a interface?

A.    Verify that the iSCSI protocol is licensed for svm1.
B.    Cycle the upstream switch port down and back up again.
C.    Verify network connectivity between the host and LIF.
D.    Verify that the iSCSI protocol is started on svm1.

Answer: B

QUESTION 20
You want to verify that a host will be able to see the storage.
A LUN is mapped to an igroup for the host, and both the host and storage are connected to FC switches.
Which command will provide the path status information from the switch?

A.    configure
B.    cfgshow
C.    fcping
D.    zoneshow

Answer: B

QUESTION 21
Click the Exhibit button.
cl01::> net int show -¬vserver
svm1
(network interface show)
Logical Status Network
Current Current Is
Vserver Interface Admin/Oper
Address/Mask Node Port Home
----------- --------- ------
---- ------------------ -----
------- ------ ----
svm1
fc_lif1 up/up
20:0b:00:a0:98:4e:ba:14
cl01-01 3a true
fc_lif2 up/up
20:0c:00:a0:98:4e:ba:14
cl01-02 3a true
lif1 up/up 172.16.21.31/24
cl01-01 a0a true
lif2 up/up 172.16.21.32/24
cl01-02 a0a true
4 entries were displayed.
cl01::>
Referring to the exhibit, a customer needs to move LIF "fc_lif1" to a new port.
Which three actions must be performed to accomplish this task? (Choose three.)

A.    Remove LIF from the existing portset.
B.    Quiesce all hosts accessing LUNs over the LIF.
C.    Take the LIF offline.
D.    Update the switch zone to include the new WWPN.
E.    Move the LIF to a new home port using thenetwork interface modifycommand.

Answer: CDE

QUESTION 22
In a 4-node cluster, how many LIFs are required on each node to allow a host to use ALUA and have multiple optimized paths to each LUN?

A.    1
B.    2
C.    4
D.    6

Answer: B

QUESTION 23
Click the Exhibit button.
cl01::>lun resize ¬-vserver
svm1 ¬-volume db1_vol -¬lun db1
-size 4096g
Error: command failed: New
size exceeds this LUN's
initial geometry
cl01::>
What is the reason for the error shown in the exhibit?

A.    The LUN is thin provisioned, but the parent volume is thick provisioned and cannot satisfy the request.
B.    The aggregate over commitment threshold has been exceeded.
C.    The parent volume that contains the LUN is out of space.
D.    The LUN cannot be grown past its maximum resize size.

Answer: D
Explanation:
http://community.netapp.com/t5/VMware-Solutions-Discussions/lun-resize/td-p/8608 2

QUESTION 24
You are asked to configure the Service Processor on a newly installed node, and must verify the following command:
system-service processor network modify ¬-node local ¬-address-family IPv4 --enable true
-ip-address 192.168.123.98 -¬netmask 255.255.255.0
Which statement about this command is true?

A.    -nodeshould reference the actual node name.
B.    The gateway IP address is missing.
C.    The Link Local IP Address is missing.
D.    IPv6 is required for the SP.

Answer: A

QUESTION 25
Inside of an SVM, an iSCSI IP address is defined on which object?

A.    qtree
B.    LUN
C.    LIF
D.    node part

Answer: C
Explanation:
https://library.netapp.com/ecmdocs/ECMP1196907/html/GUID-CEE760DF-A059-4018-BE6C-6B3A034CB377.html 3

QUESTION 26
Which protocol allows to access a controller's CLI interface?

A.    SSH
B.    NTP
C.    TFTP
D.    IMAP

Answer: A
Explanation:
https://library.netapp.com/ecm/ecm_download_file/ECMP1196798(page 4 11)

QUESTION 27
Microsoft ODX supports which scenario on clustered Data ONTAP 8.3?

A.    moving a VHDX with both SMB 3.0 and SAN protocols as either source or destination
B.    moving a VHDX from an SMB 3.0 source to an SMB 3.0 destination with no SAN support
C.    moving a VHDX from a SAN LUN source to a SAN LUN destination with no SMB support
D.    moving a VHDX with both SMB 2.1 and SAN protocols as either source or destination

Answer: A

QUESTION 28
You are zoning a fabric for a clustered Data ONTAP storage system.
After cabling, you see the following addresses logged into the fabric:
20:04:00:a0:98:16:db:9c
50:0a:09:83:8d:b1:ce:c3
What should be included in the zone configuration?

A.    50:0a:09:83:8d:b1:ce:c3 and the initiator WWNN
B.    50:0a:09:83:8d:b1:ce:c3 and the initiator WWPN
C.    20:04:00:a0:98:16:db:9c and the initiator WWPN
D.    20:04:00:a0:98:16:db:9c and the initiator WWNN

Answer: C

QUESTION 29
A customer is experiencing slower than expected performance on a database connected to an iSCSI LUN. They are surprised that performance has decreased even though they have upgraded from a 1 GB to a 10 GB switch.
What are three causes for this problem? (Choose three.)

A.    Spanning Tree is incorrectly configured on the cluster nodes.
B.    There is a faulty cable or SFP in the data path.
C.    There is an MTU mismatch between the hosts, controllers, and switch.
D.    Flow control is incorrectly set on either the host or controllers.
E.    Routing is not set up between the iSCSI and cluster networks.

Answer: ABC

QUESTION 30
Click the Exhibit button.
 
A customer has deployed a new FAS8080EX running clustered Data ONTAP 8.3.
Host A is running multipath software that has been properly configured.
Also, Host A is currently accessing a LUN using the FC protocol stored on Node A.
Switch A, shown in the exhibit, fails.
What will happen next?

A.    Node A will panic causing a storage failover to Node B.
B.    Host A will lose all access to its LUN.
C.    Host A will continue to access its LUN using Switch B through Node B.
D.    Host A will continue to access its LUN using Switch B through Node A.

Answer: B


!!!RECOMMEND!!!

1.|2017 Version NS0-507 Exam Dumps (PDF & VCE) 528Q&As Download:
http://www.braindump2go.com/ns0-507.html

2.|2017 Version NS0-507 Study Guide Video:

YouTube Video: YouTube.com/watch?v=W4qwgESs2qA 5

Links:
  1. https://library.netapp.com/ecmdocs/ECMP1368525/htm l/GUID-5CC27202-A43F-429F-AB13-C70E7CD58E09.html
  2. http://community.netapp.com/t5/VMware-Solutions-Di scussions/lun-resize/td-p/8608
  3. https://library.netapp.com/ecmdocs/ECMP1196907/htm l/GUID-CEE760DF-A059-4018-BE6C-6B3A034CB377.html
  4. https://library.netapp.com/ecm/ecm_download_file/E CMP1196798(page
  5. http://www.youtube.com/watch?v=W4qwgESs2qA
Post date: 2017-03-10 02:35:03
Post date GMT: 2017-03-10 02:35:03

Post modified date: 2017-03-10 02:35:03
Post modified date GMT: 2017-03-10 02:35:03

Export date: Thu Mar 28 13:01:59 2024 / +0000 GMT
This page was exported from Braindump2go Exam Dumps Free Download [ https://www.pass4surevce.com ]
Export of Post and Page has been powered by [ Universal Post Manager ] plugin from www.ProfProjects.com